Sound Insulation Felt

Sound Insulation Felt

Soundproof felt is made of EPDM,material is light, thin, soft, tensile strength, black finish, coil packaging, easy construction, low cost, can be directly affixed to the wall or other materials surface.

Edit
Heavy-Mass Sound Barrier · Viscoelastic Vibration Damping

Sound Insulation Felt (High-Density Mass Loaded Barrier)

An ultra-thin, high-mass viscoelastic acoustic barrier engineered to block airborne noise transmission and decouple structural vibrations. Unlike porous panels that absorb room reflections, this dense EPDM membrane dampens wall resonance—delivering Rw 24–33 dB transmission loss inside drywall, floating floors, and mechanical enclosures.

Mineral-Filled EPDM Matrix · Airborne & Impact Transmission Loss (Rw Up to 33 dB)

1.2 mm, 2.0 mm & 3.0 mm master rolls
Boosts drywall STC by 8–15 dB
Asphalt-free, lead-free & odorless
LEEDINGS Sound Insulation Felt High-Density Mass Loaded Barrier Roll
Rw 24–33 dBISO 10140 / ASTM E90 tested
1.2 / 2.0 / 3.0 mmUltra-thin space-saving rolls
2.0–6.0 kg/m²High surface mass density
China & ThailandDual manufacturing hubs
Acoustic Barrier Performance

Why Specify High-Density Sound Insulation Felt?

Engineered to block airborne sound transmission and dampen structural resonance in thin wall assemblies, floating floors, HVAC ducts, and equipment enclosures without sacrificing floor area.

01

High Acoustic Transmission Loss

High surface mass (up to 6.0 kg/m²) blocks airborne sound penetration, achieving standalone transmission loss ratings from Rw 24 dB to 33 dB.

02

Viscoelastic Vibration Damping

High internal mechanical loss factor suppresses low-frequency resonance in lightweight drywall, sheet metal ducts, and mechanical equipment shells.

03

Ultra-Thin Space Optimization

Only 1.2 mm to 3.0 mm thick—maximizing usable room floor area inside stud wall assemblies compared to bulky masonry or double-stud walls.

04

Tear-Resistant & Flame Retardant

High tensile strength against stud-fastening tear, water-resistant, aging-resistant, odorless, and compliant with commercial fire retardancy codes.

Product Data

Standard Roll Specifications & Acoustic Ratings

Homogeneous mineral-filled EPDM viscoelastic composite engineered for rapid unrolling and clean utility-knife cutting across walls, floors, and ducts.

High Density EPDM Sound Insulation Barrier Texture

Confirm roll thickness, surface weight, backing option (plain or self-adhesive), and test report scope with our engineering team prior to ordering.

ThicknessRoll DimensionsSurface DensityTransmission Loss (Rw)
1.2 mm10 m × 1.0 m (10 m² / roll)Approx. 2.0–2.4 kg/m²24 dB (ISO 10140 / ASTM E90)
2.0 mm10 m × 1.0 m (10 m² / roll)Approx. 3.6–4.0 kg/m²29 dB (ISO 10140 / ASTM E90)
3.0 mm5 m × 1.0 m (5 m² / roll)Approx. 5.5–6.0 kg/m²33 dB (ISO 10140 / ASTM E90)
Polymer BaseViscoelastic EPDM synthetic polymer with ultra-fine heavy mineral powder (Barite / Calcium Carbonate).
Fire RetardancyASTM E84 Class A (US Commercial Standard) / EN 13501-1 Class B / GB 8624 B1.
Operating Temperature-40°C to +100°C (maintains elasticity without embrittlement or sagging).
Environmental & OdorNon-toxic, odorless, low-VOC emission; free of asphalt, bitumens, lead, and unbonded fibers.
Where & How to Install

Acoustic Assemblies & Installation Methods

Integrate high-mass barrier rolls into drywall partitions, floating floor screeds, wastewater pipe lagging, and sheet-metal equipment enclosures.

01

Drywall Stud Partitions (Constrained-Layer Damping)

Interleaved between two layers of gypsum plasterboard or fastened across steel/wood studs. The viscoelastic layer dampens panel coincidence resonance, boosting partition STC by 8–15 dB.

02

Floating Floor & Underlayment (Impact Damping)

Laid over structural subfloors beneath concrete screeds, hardwood planks, or laminate flooring to attenuate footstep impact noise (IIC) and structural vibration transfer.

03

Wastewater & HVAC Pipe Lagging

Wrapped around PVC drainage pipes, chilled water risers, and rectangular HVAC air ducts—blocking turbulent water rush noise and airflow whistling.

04

Equipment & Machine Enclosures

Adhered to the interior sheet-metal casing of air compressors, generators, stamping presses, and automotive cabins to suppress drum-skin vibration.

Manufacturing & Global Supply

Manufacturing Facilities in China & Thailand

LEEDINGS operates production hubs in China and Thailand to support bulk FCL container supply, custom roll widths/lengths, and OEM acoustic barrier laminations. Production location and origin documentation are confirmed according to the actual product and manufacturing process.

Palletized Master Rolls & OEM Lamination

Work directly with our engineering and export teams on 1.2 / 2.0 / 3.0 mm master rolls, aluminum-foil or closed-cell foam pipe-lagging composites, and reinforced pallet loading.

✓Standard 10 m × 1.0 m and 5 m × 1.0 m rolls (custom slit widths supported)
✓Optional factory self-adhesive backing or aluminum-foil facing for HVAC
✓Heavy-duty core tubes & palletized container export packaging
✓Country-of-origin review based on actual manufacturing
LEEDINGS Thailand and China Manufacturing Facility

Import duties and customs treatment depend on the applicable tariff classification, origin rules, and regulations in force at the time of import. No duty exemption is implied by shipping location alone.

Technical Documents

Certifications & Acoustic Submittal Reports

Share your target market, roll thickness (1.2 / 2.0 / 3.0 mm), and wall or floor assembly details so we can provide third-party transmission loss and fire test reports.

ISO 10140 / ASTM E90Laboratory airborne sound transmission loss (Rw 24–33 dB)
ASTM E84 Class AUS commercial surface burning fire test documentation
EN 13501-1 / GB 8624 B1European & international flame-retardant classifications
Asphalt & Lead-Free EPDMNon-toxic mineral-filled elastomer formulation
French VOC A+ & AgBBOdorless indoor air quality & HVAC plenum safety
Partition STC Assembly DataDrywall & floating floor detail sheets for acoustic consultants

Certification scope and validity should be verified against the specific test report and supplied product construction.

FAQ

Acoustic Engineering & Installation FAQ

What is the difference between Sound Insulation Felt and Acoustic Absorbing Panels?

They serve complementary acoustic functions. Porous acoustic panels (such as PET felt or Akupanel) are engineered for sound absorption (measured in NRC) to reduce reverberation inside a room. Sound insulation felt is a high-mass barrier engineered for sound transmission loss (measured in Rw / STC) to physically block noise from traveling through walls, floors, and ceilings into neighboring spaces.

How does sandwiching 2.0 mm insulation felt improve lightweight drywall partitions?

Standard gypsum drywall panels exhibit an acoustic coincidence dip where sound passes easily through the wall due to flexural resonance. Sandwiching our viscoelastic felt between two drywall sheets creates constrained-layer damping (CLD), flattening the resonance dip and increasing overall partition STC by 8 to 15 dB without doubling wall thickness.

Is this material safe, odorless, and suitable for commercial HVAC and residential projects?

Yes. Our formulation uses clean synthetic EPDM polymer and natural mineral powder—completely free of volatile asphalt, tar, lead, or loose fibers. It is non-toxic, odorless, and compliant with indoor air quality standards (French VOC A+ and German AgBB criteria) across temperatures from -40°C to +100°C.

Which thickness (1.2 mm, 2.0 mm, or 3.0 mm) should I choose for my project?

1.2 mm (Rw 24 dB) is commonly specified for lightweight residential partition upgrades and automotive/appliance damping; 2.0 mm (Rw 29 dB) is the standard specification for commercial drywall stud walls, hotel suites, and floating floors; 3.0 mm (Rw 33 dB) is recommended for high-isolation theaters, mechanical rooms, and heavy wastewater pipe lagging.

Can sound insulation barrier rolls be produced and shipped from Thailand or China?

Yes. LEEDINGS operates manufacturing facilities in both Thailand and China. Share your destination port, roll thickness, backing preference, and container quantity so our team can confirm the appropriate production schedule and Certificate of Origin documentation.

Work with LEEDINGS

Source Factory-Direct Sound Insulation Barrier Felt

Contact our acoustic engineering department for palletized container loading specs, laboratory transmission loss test reports, and Thailand or China export schedules.

Edit
Edit
Edit

    QUOTE NOW